Avaliação da filtração direta descendente no tratamento de água de manancial com baixa turbidez e cor elevada
Visualizar/ Abrir
Data
2019-02-21Autor
Lima, Julyenne Kerolainy Leite
http://lattes.cnpq.br/8193128609372696
Metadados
Mostrar registro completoResumo
The treatment of water is carried out by means of an association of chemical and
physical processes aimed at transforming raw water into drinking water. The adoption
of the most appropriate treatment should be made according to the physical-chemical
and biological characteristics of the raw water. Located in Rio Grande do Norte, ETA
Extremoz is a conventional type station that treats 750 l / s of water from the lagoon of
Extremoz. Although it was designed as a conventional ETA, the history of the last 24
years of the variables apparent color and turbidity of the raw water does not comply
with the recommended parameters for the adopted treatment technology and as a
consequence the ETA started to operate as a direct descending filtration from the
beginning of 2001. The need for ETA adjustments similar to ETA Extremoz indicates
the need for studies to evaluate the ideal treatment conditions for water with these
characteristics. This work aimed to evaluate to what extent direct downward filtration
can be indicated for the treatment of water with low turbidity and high color. For this,
the research compared the results of the treatment of the water in a simple sand filter
bed and a sand filter and anthracite charcoal followed by adsorption with granulated
activated carbon. The experiments were carried out in a Pilot Installation of Water
Treatment by Oxidation, Adsorption and Double Filtration, installed in the premises of
ETA Extremoz. The treated water quality was evaluated for four filtration rates, 253,
280, 310 and 340 m³ / m².day. For the simple sand filter bed, experiments were carried
out on filters with a 700 mm thick filter layer and effective grain diameter (D10) of 0.50,
0.57 and 0.87 mm. For the double bed of sand and anthracite charcoal, the thickness
of the sand filter layer was reduced to 450 mm, including anthracite coal layer with 250
mm thickness and D10 = 1,00 mm. For the adsorption in granulated activated carbon,
experiments were performed with layer of 650 mm and D10 of 0.23, 0.60 and 0.90 mm.
It is concluded that for the double bed of sand and anthracite coal all three grades and
four filtration rates studied complied with Ordinance No. 5/2017, the filter F3, for the
filtration rate of 340 m³ / m².day, the best condition to be adopted in real scale.