Mostrar registro simples

dc.creatorPinheiro, Viviane da Silva
dc.creatorLeite, José Yvan Pereira
dc.date.accessioned2016-01-21T19:42:31Z
dc.date.available2016-01-21
dc.date.available2016-01-21T19:42:31Z
dc.date.issued2013-10-22
dc.identifier.citationPinheiro, V. S., Leite, J.Y. P. (2013). Influência da qualidade da água na sedimentação caulim do Equador/RN. In XXV Encontro Nacional de Tratamento de Minérios e Metalurgia Extrativa & VIII Meeting of the Southern Hemisphere on Mineral Technology, Goiânia/GO. Universidade Federal de Goiás.pt_BR
dc.identifier.urihttp://memoria.ifrn.edu.br/handle/1044/482
dc.description.abstractThe water quality is very important to mining flotation. Chemical species dissolved in water compete with ion collector to particle surface. This competition can bring results that undertake in negative way to flotation efficiency. This paper aims to study the water quality to kaolin flotation in Equador county, at Rio Grande do Norte. Initially was realized physico-chemical analysis in water and after treatment by dissolved air flotation to remove contaminants. Flotation tests was realized at dissolved air flotation to aim the best removal contaminants. The results of water analysis showed high levels of dissolved salts, 5210µS/cm of electrical conductivity and 955,50 mg/L CaCO3 total hardness; 127, 3 mg/L Ca+2 calcium hardness and 155,08 mg/L Mg+2 magnesium hardness. The pH measurement was 7,53. Sodiun found by technical by flame fhotometry was 528 mg/L Na+pt_BR
dc.description.abstractThe water quality is very important to mining flotation. Chemical species dissolved in water compete with ion collector to particle surface. This competition can bring results that undertake in negative way to flotation efficiency. This paper aims to study the water quality to kaolin flotation in Equador county, at Rio Grande do Norte. Initially was realized physico-chemical analysis in water and after treatment by dissolved air flotation to remove contaminants. Flotation tests was realized at dissolved air flotation to aim the best removal contaminants. The results of water analysis showed high levels of dissolved salts, 5210µS/cm of electrical conductivity and 955,50 mg/L CaCO3 total hardness; 127, 3 mg/L Ca+2 calcium hardness and 155,08 mg/L Mg+2 magnesium hardness. The pH measurement was 7,53. Sodiun found by technical by flame fhotometry was 528 mg/L Na+.pt_BR
dc.languageporpt_BR
dc.publisherInstituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Nortept_BR
dc.relation.ispartofXXV Encontro Nacional de Tratamento de Minérios e Metalurgia Extrativa & VIII Meeting of the Southern Hemisphere on Mineral Technologypt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectwater quality; sedimentation; flotation; kaolin; micapt_BR
dc.subjectwater quality; sedimentation; flotation; kaolin; mica.pt_BR
dc.titleInfluência da qualidade da água na sedimentação caulim do Equador/RNpt_BR
dc.typeArtigo de Eventopt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentNatal - Centralpt_BR
dc.publisher.initialsIFRNpt_BR
dc.subject.cnpqEngenharia de minaspt_BR
dc.citation.issueXXV and VIIIpt_BR
dc.description.resumoA qualidade da água é de grande importância na flotação de minérios. Espécies químicas dissolvidas no meio aquoso competem com o íon coletor para adsorver-se na superfície da partícula. Essa competição pode trazer resultados que comprometem de maneira negativa a eficiência da flotação. Esse trabalho tem como objetivo principal estudar a qualidade da água para sedimentação de caulim do município de Equador, no Rio Grande do Norte. Inicialmente foi realizada análise físico-química na água e posterior tratamento via flotação por ar dissolvido para remoção de contaminantes. Em seguida foi realizado teste de flotação por ar dissolvido (FAD) usando como meio aquoso: água bruta de Equador. A aplicação da água bruta e tratada foi usada com a finalidade estudar os melhores parâmetros para sedimentação. Os resultados da análise de água mostraram elevada quantidade de sais dissolvidos, com condutividade elétrica de 5210µS/cm e 955,50 mg/L CaCO3 de dureza total; 127, 3 mg/L Ca+2 dureza de cálcio e 155,08 mg/L Mg+2 dureza de magnésio. A medição de pH determinou valor de 7,53. O sódio encontrado pela técnica de fotometria por chama foi de 528 mg/L Na+.pt_BR